Stringer 3 Tension Excursion · 14:32–15:08
Cluster cluster_stringer3_1432_excursion
Modules affected
14
10 Scrap · 2 B · 1 C · 1 clean
Defect rate
93%
across the cluster
Avg signature match
76%
coherence 93%
Net impact
$1,890
risk $2,380 − salvage $490
Root cause: Operator-1 raised Stringer 3 tension from 4.2 → 4.8 N at 14:32 to compensate for an alignment drift. CUSUM warning crossed at 14:35; recommendation declined; tension reverted only at 15:08 after action threshold. All 14 modules processed by Stringer 3 in the 36-minute window are members of this cluster.
Excursion timeline · 14:32 → 15:08 · 36 min
String Tension · Stringer 3
CUSUM chart
warn 4.5 · action 4.8 N
Operator raised tension from 4.2 → 4.8 N at 14:32. CUSUM warning crossed at 14:35 and action threshold at 15:08. This module passed through Stringer 3 at 14:42, in the middle of the excursion.· Green dashed: If recommendation accepted at 14:38.
Soldering Temperature · Stringer 3
I-MR chart
warn 250 · action 260 °C
Soldering iron held nominal throughout the shift; no thermal contribution to the defect.
Cell Microcrack Rate · Stringer 3
p-chart
warn 0.02 · action 0.04 proportion
Per-lot crack rate from EL screening of cells exiting Stringer 3 spiked from 0.5% to 3.8% during the tension excursion before recovering once tension reverted.
Scrap with defect B/C-tier UnaffectedEach tick = one cluster module's processing time
Affected modules · 14 total
sort
mod_showcase_crack_001
Showcase#1/14 · 14:32
Scrap101
sig 92%487 W
Branching crack adjacent busbar — classic signature.
mod_cluster_stringer3_002
#2/14 · 14:34
Scrap101
sig 88%491 W
Crack overlaps inter-cell wire — hard scrap.
mod_cluster_stringer3_003
#3/14 · 14:37
Scrap101
sig 85%478 W
Branching pattern matches predicted high-tension crack.
mod_cluster_stringer3_004
#4/14 · 14:39
Scrap101
sig 90%482 W
Multi-finger crack, very strong signature match.
mod_cluster_stringer3_005
#5/14 · 14:42
Scrap101
sig 79%503 W
Smaller crack but overlaps wire — Scrap.
mod_cluster_stringer3_006
#6/14 · 14:44
Scrap101
sig 81%495 W
Branching pattern, busbar adjacent.
mod_cluster_stringer3_007
#7/14 · 14:47
Scrap102
sig 74%514 W
Crack outside wire but A-tier limit exceeded.
mod_cluster_stringer3_008
#8/14 · 14:49
Scrap102
sig 71%522 W
Edge-region crack.
mod_cluster_stringer3_009
#9/14 · 14:52
Scrap102
sig 76%519 W
Outside-wire crack, similar tension signature.
mod_cluster_stringer3_010
#10/14 · 14:55
Scrap102
sig 68%525 W
Mild outside-wire crack.
mod_cluster_stringer3_011
#11/14 · 14:57
Tier B102
sig 63%548 W
Below A-tier limit — B-tier with note.
mod_cluster_stringer3_012
#12/14 · 15:00
Tier B102
sig 61%551 W
Small crack, marginal — B-tier.
mod_cluster_stringer3_013
#13/14 · 15:02
Tier C101
sig 58%532 W
Small branching crack — C-tier on wire-overlap reduction rule.
mod_cluster_stringer3_014
#14/14 · 15:05
Tier Ano defect
sig 0%612 W
Escaped — passed through after CUSUM warning but before crack initiation threshold.
Cluster Bayesian coherence — is this one cluster or many?
Confidence that all 14 modules share a single causal root:93%
Predicted signature
Branching crack near busbar on cells passing through Stringer 3 at ≥4.5 N tension
Observed signature
Branching crack patterns observed on 13 of 14 affected modules, 1 unaffected
Average signature match across affected modules: 76%. High coherence means the defects look like the same phenomenon — strong evidence of a common cause.
Economic impact
Total modules affected14
Scrap10
B-tier2
C-tier1
Unaffected (A-tier)1
Revenue at risk$2,380
Salvage realised$490
Net impact$1,890
If the platform's recommendation had been accepted at the right moment, projected savings:~$1,607 across this cluster.
Cluster-wide recommendations
Re-train Operator-1 on stringer tension SPC thresholds
shift
Recommendation declined twice in this shift across different modules.
→ Faster acceptance of CUSUM-driven recommendations.
Implement automatic tension hold when CUSUM warning crosses for ≥5 min
process
Would have prevented this 36-minute excursion regardless of operator decision.
→ Estimated 13/14 cluster outcomes prevented in similar future events.
Add 'cluster forecast' tile to operator UI showing real-time blast radius
station
Operator could not see the projected impact of declining the 14:38 recommendation.
→ Better-informed real-time decisions.
This cluster page shows how a single upstream excursion produces a coherent pattern across many modules. In production, every excursion that exceeds SPC thresholds is automatically grouped into a cluster, and cluster-level analysis runs continuously.