Sim time08:00:00
Speed60×
Shift A · Day 1

Maintenance

Asset health · vibration FFT · predictive runout
M39M40M41M52M60M66M68M83
TCO target life
47%
Assets monitored
6
Below 60% health
0
Cleaning bath age
26.0 h

Asset fleet · sorted by health

Maintenance schedule · next 5

Vacuum Pump 1lamination
est. failure in ~6917h · health 88%
TCO Cathode 2tco
est. failure in ~8500h · health 90%
Stringer Head 1stringing
est. failure in ~8700h · health 92%
Lamination Press 1lamination
est. failure in ~8800h · health 93%
TCO Cathode 1tco
est. failure in ~9000h · health 95%

Vibration FFT · TCO Cathode 1

M52
1× imbalance
0.50
2× misalign
0.16
BPFO
0.13
BPFI
0.09
Broadband
0.18

BPFO/BPFI peaks indicate bearing race spalling. Rising broadband floor → cavitation or generalized wear. 2× growth → coupling misalignment.

Health projection · next 24h

M39